NEXPO Products

IED PRODUCTS

We provide 'innovation at every level' in order to control rofitability as well as efficiency, safety, cyber security, the environment, and risk factors of reliability, utilizing the advanced technological prowess of both NEXPO Co., Ltd. and Schneider Electric.

VAMP 59

P12X P12Y P13X P14X P22X P24X P34X P43X P44X P44Y P521 P53X P54X P59X P63X P64X P72X P74X P746 P79X P821 P841 P849 P92X P3Advanced P3Standard VAMP50_52 VAMP55 VAMP57 VAMP59 VAMP210 VAMP230 VAMP259 VAMP265 VAMP265M VAMP300G VAMP300F VAMP300T

VAMP 59

Image Description

description

VAMP 50 Series
Protection for LV and MV feeders and motors
VAMP 50 series offers a comprehensive selection of modular protection relays for overcurrent, earth fault, voltage, frequency and line differential protection.

VAMP 50 Overcurrent and Earth Fault Protection Relay
VAMP 52 Feeder and Motor Protection Relay

VAMP 50: Low and medium voltage feeders in industrial and utility applications with optional arc flash protection and for back-up protection.

VAMP 52: Low and medium voltage feeders in industrial or utility applications with optional arc flash protection. Extensive thermal protection functions make this relay optimal for low and medium-sized asynchronous motors. In feeder configuration mode, autoreclose and directional earth fault are also available.

VAMP 55: Frequency and voltage protection for both utility and industrial applications and also for synchro check applications.

VAMP 59: Line differential protection in medium voltage systems including overhead lines and cables with optional arc flash protection. Intermediate power transformers can be applied within the protected zone.

Specification

VAMP 59

Description Specification
Type (Model Name) VAMP 59
Auxiliary Power Supply 24Vdc
48-230Vac/dc
CT Inputs 4
VT inputs 1
Number of Digital input (max) 7
Number of Digital Output (max) 6
Analogue input Option
Analogue Output
RTD input
Protection Elements Phase unbalance protection (46)
Thermal overload (49)
Ground fault (50N/51N)
3 Phase overcurrent (50/51)
Circuit breaker failure (50BF)
Ground fault directional (67N)
Magnetising inrush (68F2)
Transformer overexcitation (68F5)
Auto-reclose (79)
Phase segregated current differential (87L)
Current transformer supervision / VT supervision (CTS/VTS)
Communication Protocol IEC60870-5-101, IEC60870-5-103, DNP3.0, Modbus, SPA-bus, Ethernet IP, Profibus DP, IEC61850

Download

VAMP 59

File Download
User Manual Download
Product Catalog Download

Question

Got a question? We'd love to hear from you!

Address

1106, Woolim Lion's Valley rd Bld, 24, 388Gil, Dunchondaero, Jungwon-Gu, Seongnam-Si, Kyeonggi-Do, Korea (13403)

Phone Number

+82 31 739 9200

Email

mhcha@nexpo.kr

성공적으로 접수가 되었습니다.
빠른시간에 연락드리겠습니다. 감사합니다.


This is Our Client