MiCOM P34X
Generator Protection Relays
MiCOM generator protection relays provide flexible and reliable integration of protection, control, monitoring and measurement functions for small, medium and large generators.

Specification

Description Specification
Type (Model Name) P342 P343 P344 P345
Auxiliary Power Supply 24-32Vdc
48-110Vdc/40-100Vac
110-250Vdc/100-240Vac
CT Inputs 5 8 8 9
VT inputs 4 4 5 6
Number of Digital input (max) 24 32
Number of Digital Output (max) 24 32
Number of Analog Input (optional) 4
Number of Analog Output (optional) 4
Number of RTDs (optional) 10
Protection Elements Under-impedance (21)
Overfluxing (24)
Check synchronising (25)
100 % stator earth fault (3rd) (27TN/59TN)*
Directional power (32)
Undercurret (37P/37N)
Thermal overload (38/49)
Loss of field (40)
Negative sequence overcurrent (46)
Negative sequence thermal (46T)
Negative sequence over voltage (47)
Unintentional energisation (50/27)
Ground fault (50N/51N)
3 Phase overcurrent (50/51P)
Circuit breaker failure (50BF)
Interturn / split phase (50DT)
Voltage controlled overcurrent(51V)
Over / Under voltage (59/27)
Residual over voltage (59N)
Restricted earth fault (64)
Wattmetric earth fault (64N/32N)
Rotor earth fault (64R) (MiCOM P391 option)
100 % stator earth fault (low frequency) (64S)
Ground fault directional (67N)
Wattmetric sensitive earth fault (67W)
Pole slipping (78)
Turbine abnormal frequency (81AB)
Under / Over frequency (81)
Generator differential (87G/87GT)
Current transformer supervision / VT supervision (CTS/VTS)
Communication Protocol IEC60870-5-103, DNP3.0, Modbus, K-bus/Courier, IEC61850

Download

File Download
User Manual Download
Product Catalog Download

Question

Got a question? We'd love to hear from you!

Address

1106, Woolim Lion's Valley rd Bld, 24, 388Gil, Dunchondaero, Jungwon-Gu, Seongnam-Si, Kyeonggi-Do, Korea (13403)

Phone Number

+82 31 739 9200

Email

mhcha@nexpo.kr

성공적으로 접수가 되었습니다.
빠른시간에 연락드리겠습니다. 감사합니다.


This is Our Client